6U VME64x 3200
The VME 3200 crate series provides industry standard VME crates with redundant and hot-swappable front-side plugged in 500W cPCI power supplies in a compact and rugged design. The VME card sized CML shelf manager allows full remote monitoring and control of power supply, fan and chassis.
Efficient cooling of VME modules is done by the 1U fan tray which is is removable and completely controlled.
Main Features
- 7U VME-Bin VM4 with 16 Slots for 6Ux160mm VME modules, slot 17 used for CML, rugged construction with 3mm thick side panels
- 16 slot J1/J2 monolithic VME64x backplane, 8 layer PCB, active termination, active automatic-daisy-chain
- Plug-in, replaceable VME fan tray UL 4 with high efficient 3- fold DC fan tray blowers, one unit height, air inlet from bottom, optionally watched by temperature sensors and / or variable fan speed, fan fail detection
- Outfitted with one or two 500W cPCI power supplies, hot-swappable, redundant operation,
- Dimensions: 19” (482mm) x 7U (311mm) x 298mm [whd], weight: ca. 11 kg
- 7U VME-Bin VM4 with 16 Slots for 6Ux160mm VME modules, slot 17 used for CML, rugged construction with 3mm thick side panels
- 16 slot J1/J2 monolithic VME64x backplane, J0 optional, 8 layer PCB, active termination, active automatic-daisy-chain
- Plug-in, replaceable VME fan tray UL 4 with high efficient 3- fold DC fan tray blowers, one unit height, air inlet from bottom, optionally watched by temperature sensors and / or variable fan speed, fan fail detection
- WIENER CML01 Shelf manager for local and remote monitoring and control, monitoring of all DC voltages (under/over voltage, temperatures, detection and generation of VME signals (SYSRES, SYSFAIL, ACFAIL), local / remote ON/OFF and SYSRES, Ethernet interface with integrated web-server and SNMP protocol, USB interface for local PC control, 8 digital inputs and outputs and 4 analog inputs, 10 LED’s on front panel
- 100V – 240V world-wide auto-range AC input, with power factor correction, CE-conformity
- Dimensions: 19” (482mm) x 7U (311mm) x 298mm [whd]
- Weight: ca. 11 kg, (with CML and one cPCI power supply)
Standard configurations (other possible on request)
Crate Version | Backplane | +5V | +3.3V | +12V | -12V |
---|---|---|---|---|---|
VME64x 3200_1 | J1/J2 VME64x | 50A | 40A | 5A | 2A |
VME64x 3200_2 | J1/J2 VME64x | 100A | 80A | 10A | 4A |
VME64x 3200_1P0 | J1/J0/J2 VME64x | 50A | 40A | 5A | 2A |
VME64x 3200_2P0 | J1/J0/J2 VME64x | 100A | 80A | 10A | 4A |
VME64x Backplanes
All WIENER VME 64x multi-layer backplanes are outfitted with 5-row 160 pin connectors for J1 and J2 as well as optionally with 133 pin hard metric connector for J0. The busses have active on board termination and active automatic daisy-chain (CBLT compatible!). Available with up to 21 slots.
W-Ie-Ne-R’s special current multilayer made of “z”-bended copper sheets, further stiffens the 4.8mm thick board.
- Strip line technology suitable for data rates of 320Mbyte/s (64bit)
- High power distribution by current multiplayer / bus bar system
- Excellent RF shielding
- Optimized filtering (electrolytic and ceramic filter-capacitors)
- Minimized ground shift and cross talk
- Automatic daisy chain
- flat cable connector for sense and control
- Provision for up to 8 temperature sensors (module temp. checking)
- Sense circuit protection by PTC- resistors (Optionally)
- Special version for VIPA (VME in Physics) and CERN VME430 style
Power per slot | VME 64x | VME 64x-V430 | VME64xP |
---|---|---|---|
(20°C / 70°C) | J1-J0-J2 | J1-Jaux-J2 |
J1-J0-J2 Slot 2- 21 |
3,3V | 17A / 12A | 17A / 12A | 17A / 12A |
5V | 15,3A / 10,8A | 15,3A / 10,8A | 27A / 19A |
+/-12V | 1,7A / 1,2A | 1,7A / 1,2A | 1,7A / 1,2A |
+/-15V | 3,2A / 2,5A | ||
-5,2V | 19A / 15A | ||
-2V | 9,5A / 7,5A | ||
Vw, Vx, Vy, Vz | 4A / 3A | ||
V1, V2 | 1,7A / 1,2A | 1,7A / 1,2A | 1,7A / 1,2A |
Layers | 10 | 10 | 18 |
VME / VME64x Series 3200 | |
---|---|
Module cage formats | 6U´160mm, VME standard, Transition 6U ´ 80mm |
Crate Size | 19“ or 435mm ´ 7U (311mm), 298mm depth |
Mains input |
wide range: 90...265VAC, 47-63Hz, 10A fuse, Inrush current less than 30A at 230Vac. |
Isolation | Inp.-outp. CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 |
Regulation | Typ. ±1-±4%. (Various with output voltage.) |
Noise and ripple: | <50mVpp, typical <30mVpp (0-20MHz ), <3mVrms (0-2MHz) |
Operation: |
0...40°C without derating, rel. humidity 30...80%, non condensing atmospheric pressure 70...110kPa, for 600W continuous power >85kPa |
Storage: | -30°C up to 85°C |
Stability: | 10mV or 0,1% within 24 hours ; 25mV or 0,5% within 6 months |
Overvoltage protection: | trip off, protection against broken sense lines |
Internal temperature limits: | Cut off: 110°C heat sink, 70°C ambient, >45°C module exhaust accelerates fan speed to 100% |
Cooling air flow (max. fan speed): | removable fan, 340m3h, blower MTBF >60 000h (40°C) |
Efficiency: | max. ca. 80%, depends on installed output voltages |
Product Data Sheet | |
---|---|
6U VME64x 3200: | Print Product Data Sheet |
Documentation | |
---|---|
Manual and Tech-Notes : | Crates_3000 |
Introduction in to VME: | WIENER_VME_VXI_VXS_introduction |
Downloads | |
---|---|
SYScontrol : | Download |
SNMP: | Download |
OPC-Server: | Download |